Energy monitoring and sub-metering for industrial sites

See where every kilowatt goes: meters in your switchboards, live energy screens and reports that show which lines, machines and pumps are driving the power bill.

Plant monitoring dashboard demo with production, utilities and energy tilesCustom switchboard built in the AMC Griffith workshop

SVC · Energy monitoring · What we do

You can't cut what you can't measure.

Most sites get one number each month: the total on the power bill. It doesn't say which line, cool room, compressor or pump is using the energy, when the demand peaks happen, or why the bill has gone up. Without that, energy decisions are guesswork.

AMC fits energy meters where they tell you something useful: on incomers, MCCs, distribution boards and the big loads. We connect them to your PLC, HMI or SCADA so energy shows up next to production, then set up screens, alarms and reports your team will actually use. Because we also build switchboards and program control systems, metering can go into a new board from day one or be added to the boards you already have.

What we do

  • Sub-metering in new and existing switchboards and MCCs
  • Energy screens in SCADA and HMI
  • Energy per unit, per shift and per line reporting
  • Peak demand and load profile monitoring
  • Power factor correction
  • Power quality logging and investigation
  • Solar, battery and generator monitoring
  • Pump and irrigation energy monitoring

Standards, platforms & tools

Schneider PowerLogicSiemens SENTRONABBSatecCarlo GavazziModbusAS/NZS 3000AS/NZS 61439

What we set up

From meters to decisions.

A typical energy monitoring job runs in these steps. We can do one part or the whole thing.

01

Find the big loads

We walk the site and your switchboards with you, look at the bills and decide where meters will tell you the most.

02

Meter the boards

Energy meters and current transformers fitted to incomers, MCCs and key circuits, in new boards or retrofitted to existing ones. See switchboards and MCCs.

03

Connect the data

Meters networked into your PLC or SCADA, or a standalone gateway where there is no control system yet. See PLC and SCADA.

04

Show it clearly

Live screens for kW, kWh, demand and power factor, plus energy per unit or per tonne next to production. Try the energy tile in our plant monitoring demo.

05

Fix power factor and quality

Power factor correction where it pays, and power quality logging to find the cause of trips, flicker or failing equipment.

06

Keep it running

Alarms for unusual consumption or demand, monthly reports, and support if a meter or link drops out.

Where it helps

Built for processing plants, sheds and farms.

In food and beverage plants, cold storage and packing sheds the biggest energy users are usually refrigeration, compressed air, pumps and heating. Metering them separately shows which one to look at first and whether a change actually saved anything.

On farms and irrigation sites, monitoring pump energy against flow shows when a pump is wearing or a system is working harder than it should. Solar, battery and generator monitoring shows what your own generation is really doing. We are electrical contractors, so all the work behind the main meter is done by our licensed team; the network or retailer meter at the supply point stays with your metering provider.

  • Site walk and bill review
  • Metering plan and upfront price
  • Meters fitted, often during planned shutdowns
  • Connected to PLC, SCADA or a gateway
  • Screens, alarms and reports set up
  • Support and changes afterwards

Proof

See it on the job.

See live energy readings next to production, utilities and machine status in our working plant monitoring demo, and the switchboards we design and build in Griffith.

Where we work

Griffith-based. Riverina and Australia-wide.

We set up energy monitoring across Griffith, Leeton, Wagga Wagga and the Riverina, and on projects Australia-wide.

GriffithLeetonYendaHanwoodYoogaliNarranderaDarlington PointColeamballyHayHillstonWagga WaggaMildura

FAQs

Common questions

What is sub-metering?

Sub-metering means fitting your own energy meters behind the main meter so you can see how much energy each part of the site uses, such as a production line, cool room, compressor or pump. It is for your own monitoring, not for billing by your retailer.

Can you add meters to our existing switchboards?

Usually yes. We check space, ratings and access, then fit meters and current transformers to the existing board, often during a planned shutdown. If a board is too old or full, we can advise on an upgrade.

Which meters do you use?

We work with Schneider PowerLogic, Siemens SENTRON, ABB, Satec and Carlo Gavazzi meters, and pick the one that suits the job and your existing systems.

Can energy data go into our existing SCADA or PLC?

Yes. Meters can be networked into most PLC and SCADA systems, so energy sits next to production data. Where there is no control system, we use a standalone gateway and dashboard.

Do you do power factor correction?

Yes. We assess power factor from meter or logger data and supply and install power factor correction where it makes sense for your tariff and load.

Do you install smart meters for electricity retailers?

No. The meter at your supply point belongs to your metering provider. We install and look after private energy meters and monitoring behind it.

Next step

Got a plant, machine or board that needs sorting?

Send us the scope, drawings or a few photos. An engineer reads every request and comes back within one business day with next steps and a clear, upfront price.

Project engineer or OEM? Send a P&ID, equipment list or scope for a budget price.

Call nowEmailGet a quote