Hazardous area classification is the process of working out where a flammable gas, vapour or combustible dust could form an explosive atmosphere, how often, and how far it could spread. The result is a set of zones shown on a hazardous zone drawing. Every electrical item installed in those zones has to be selected to suit them. This guide explains how Zone 0, Zone 1 and Zone 2, and dust Zones 20, 21 and 22, are worked out, and what good classification paperwork looks like.
The short answer
- Gas and vapour zones are classified to AS/NZS IEC 60079.10.1:2022, which adopts IEC 60079-10-1:2020
- Combustible dust zones are classified to AS/NZS 60079.10.2:2016, which adopts IEC 60079-10-2:2015
- Zones depend on the material, the sources of release, how often and how much is released, and the ventilation
- The site owns the classification. The person in control of the installation is responsible for having it done; electricians use it to select and install equipment
- The paperwork (classification report, zone drawings and verification dossier) is what an inspector or auditor will ask for first
For the wider picture of hazardous area electrical work, including equipment protection types and inspection, see our EEHA hazardous area guide. This guide goes deeper on classification and drawings.
Gas zones and dust zones
| Zone | Material | How often an explosive atmosphere is present | Typical places | Equipment protection level |
|---|---|---|---|---|
| Zone 0 | Gas or vapour | Continuously, for long periods or frequently | Vapour space inside a spirit or fuel tank | Ga |
| Zone 1 | Gas or vapour | Likely to occur occasionally in normal operation | Around open filling points, vents and sample points | Ga or Gb |
| Zone 2 | Gas or vapour | Not likely in normal operation, and only briefly if it does | Around flanges, valves and pump seals that only leak if something fails | Ga, Gb or Gc |
| Zone 20 | Combustible dust cloud | Continuously, for long periods or frequently | Inside silos, bucket elevators, hammer mills and dust filters | Da |
| Zone 21 | Combustible dust cloud | Likely to occur occasionally in normal operation | Around bag tipping and open transfer points | Da or Db |
| Zone 22 | Combustible dust cloud | Not likely in normal operation, and only briefly if it does | Around enclosed conveyors and building areas where dust can escape or settle | Da, Db or Dc |
Zone 0 and Zone 20 are usually confined to the inside of tanks, silos and process equipment. Most of the classified area on a typical site is Zone 2 or Zone 22, around equipment that only releases material when something goes wrong. Areas outside every zone are classed as non-hazardous, and the drawing should show where that boundary sits.
The equipment protection level (EPL) in the last column is how the zone links to equipment selection. Equipment marked Gb, for example, is suitable for Zone 1 and Zone 2. The gas group (IIA, IIB, IIC), dust group (IIIA, IIIB, IIIC) and temperature class also have to suit the material, and the classification report should state them.
Sources and grades of release
Classification starts by listing every point where flammable material can escape: tank vents, open filling points, pump seals, flanges, valve stems, sample points, bag tipping stations and dust filter discharges. Each source is given a grade of release:
- Continuous: released continuously or for long periods, such as the surface of an open spirit tank
- Primary: expected to release periodically or occasionally during normal operation, such as a vent that breathes during filling
- Secondary: not expected in normal operation, and only infrequently and briefly if it does, such as a flange gasket or a pump seal failure
As a general guide, a continuous grade of release tends to create Zone 0 or Zone 20, a primary grade Zone 1 or Zone 21, and a secondary grade Zone 2 or Zone 22. Ventilation can shift that outcome either way.
Ventilation and zone extent
For gas and vapour, ventilation is the biggest factor in both the zone type and how far it extends. AS/NZS IEC 60079.10.1 looks at two things:
- Degree of dilution: high, medium or low, depending on the release rate compared with the air movement available to dilute it
- Availability: good, fair or poor, depending on how reliably that ventilation is present. Natural ventilation outdoors behaves differently from a fan that can fail
The size of each zone is then worked out from the release rate, the properties of the material (lower flammable limit, density and volatility) and the ventilation. The standard and its Supplement 1 give methods and worked examples. Typical layouts from recognised codes, such as AS 1940 for flammable and combustible liquids storage and AS/NZS 1596 for LPG, can be used where the installation matches them. Anything unusual must be classified from first principles.
For dust, housekeeping matters as much as ventilation. Dust that settles in layers can be stirred into a cloud, and layers can also ignite from hot surfaces. AS/NZS 60079.10.2 expects the classification to assume a level of housekeeping, so that assumption has to be stated and then actually achieved.

Need a hazardous area classification? We prepare zone drawings and dossiers, then design and install to suit. Send us the scope, drawings or a few photos and an engineer will reply within one business day.
What a hazardous zone drawing should show
The zone drawing is what people on site actually use, so it needs to be clear and current. A good drawing shows:
- A plan, and sections or elevations where zones extend vertically, drawn to scale on an up-to-date site layout
- Each zone shaded or hatched, with a legend that follows the conventions in the standard
- Dimensions for each zone measured from the source of release, including heights above ground and around vents
- The material, its gas or dust group and the temperature class required
- Pits, trenches, drains and other low points where heavier-than-air vapours can collect
- References back to the source of release schedule and classification report
- A revision number, date and the name of the person who did the classification
The drawing and its supporting report should be updated whenever the process, materials, layout or ventilation changes. A new tank, a moved vent or a wall built around an outdoor area can all change the zones.
Who can classify a hazardous area
The person with management or control of the site has the duty to ensure classification is done. The classification itself should be carried out by people competent in it, with input from process, operations and maintenance staff who know how the plant actually runs. The competency framework for hazardous area work is set out in AS/NZS 4761.1, and there are specific national units of competency for hazardous area classification. In Queensland, inspectors look for a hazardous area classification specialist to have been engaged.
A licensed electrician installing equipment is not responsible for the classification, but should not install anything in a hazardous area without one.
The verification dossier
AS/NZS 60079.14 (now the 2022 edition) requires a verification dossier for every hazardous area installation. It is a live record kept for the life of the installation. Typical contents include:
- The hazardous area classification report and zone drawings
- Material data: gas or dust group, temperature class and safety data sheets
- An equipment schedule with each item's location, protection type, EPL and certificate of conformity, including any specific conditions of use
- Intrinsic safety system descriptions and calculations, where used
- Installation drawings, cable schedules and the initial detailed inspection records
- Competency records for the people who designed, installed and inspected the work
- Later inspection, maintenance, repair and modification records, following AS/NZS 60079.17
In some states, hazardous area installations also have to be inspected or audited before they are first connected. Queensland, for example, requires an accredited auditor inspection. Check the rules in your state early in the project.
Typical regional sites
- Wineries and distilleries: spirit used for fortification, high-strength spirit tanks, stills, barrel rooms with spirit and bottling of spirits all need assessing. Our winery electrical and automation page covers this work
- Grain, feed and rice handling: silos, bucket elevators, hammer mills, dust filters and enclosed conveyors are classic dust zone sites
- Biomass and pellet plants: wood dust from milling, drying, pelletising and storage, plus hot surfaces in dryers
- Fuel storage and dispensing: diesel and petrol depots, farm fuel tanks and refuelling points
- Biogas: digesters, gas holders, flares and gas engines at wastewater plants, piggeries and food processors
- LPG: storage vessels, filling and vaporiser installations for kilns, dryers and forklifts
How AMC helps
AMC designs, installs and inspects electrical equipment in hazardous areas to AS/NZS 60079. We work from your classification, or bring in and coordinate a classification specialist where one is needed, then design the equipment selection, build the control panels in our Griffith workshop, install to suit the zones and put together the verification dossier. We work across the Riverina, NSW and Victoria.
This guide is general information. Hazardous area classification must be carried out by competent people for your specific site, materials and process, using the current editions of AS/NZS 60079 and any industry codes that apply. Written by the AMC Electrical & Automation engineering team in Griffith, NSW. Last checked November 2026.
FAQs
Common questions about hazardous area classification
What is the difference between Zone 1 and Zone 2?
In Zone 1 an explosive gas atmosphere is likely to occur occasionally during normal operation. In Zone 2 it is not likely in normal operation, and if it does occur it only lasts a short time, for example after a gasket or seal fails.
What are dust Zones 21 and 22?
They are the dust equivalents of gas Zones 1 and 2. Zone 21 is where a combustible dust cloud is likely occasionally in normal operation, and Zone 22 is where it is not likely and only brief if it happens. Zone 20 is the dust equivalent of Zone 0, usually inside silos, elevators and filters.
Who is responsible for hazardous area classification?
The person with management or control of the site, usually the owner or operator. The classification should be done by people competent in it, and electricians then use it to select and install equipment.
Which standards are used to classify hazardous areas in Australia?
AS/NZS IEC 60079.10.1:2022 for gases and vapours and AS/NZS 60079.10.2:2016 for combustible dusts. Industry codes such as AS 1940 for flammable liquids and AS/NZS 1596 for LPG also give typical zone layouts.
What is a verification dossier?
It is the set of records required by AS/NZS 60079.14 for a hazardous area installation: the classification and zone drawings, equipment certificates and schedules, installation and inspection records, and competency records. It is kept up to date for the life of the installation.
Does a winery need a hazardous area classification?
If it stores or handles spirit for fortification or distilling, or has other flammable materials such as LPG, those areas need assessing. Our winery electrical and automation team can help scope the work.
How often should a zone drawing be reviewed?
Whenever the process, materials, layout or ventilation changes, and as part of periodic inspections. An out-of-date drawing can lead to the wrong equipment being installed.
Next step
Got a plant, machine or board that needs sorting?
Send us the scope, drawings or a few photos. An engineer reads every request and comes back within one business day with next steps and a clear, upfront price.
Project engineer or OEM? Send a P&ID, equipment list or scope for a budget price.